Compact Size Class0.5 ADW350 Wireless Metering Meter High Precision
Contact Person : Dina Huang
Phone Number : 18761502682
WhatsApp : +8618761502682
Detail Information |
|||
Highlight: | Iot Power Meter,Alarm ACREL ADW300 Power Meter,ACREL ADW300 Power Meter |
---|
Product Description
Product Features
Multiple Communication Methods ● 4G LTE ● NB-IoT ● WiFi (2.4GHz&5GHz) ● LoRa ● RS485 (MODBUS-RTU) ● Paired with IoT Energy Monitoring System |
![]() |
Power Quality Analysis ● Total Harmonic ● 2nd~31st Harmonic ● Voltage Unbalance ● Current Unbalance |
![]() |
Expanded Function ● 2-channel DO (Digital Ouput) ● 4-channel DI (Digital Input) ● 4-channel Cable Temperature Monitoring ● 1-channel Residual Current Measurement |
![]() |
Alarm Function ● Over/Under Current ● Over/Under Voltage ● Over/Under Power ● Phase Loss |
![]() |
Wiring Illustration
![]() |
![]() |
ADW300-4GHW Wiring&Installation Instruction (3P4W) ADW300-4GHW Wiring&Installation Instruction (3P3W)
![]() |
![]() |
ADW300-WF Wiring&Installation Instruction (3P4W) ADW300-WF Wiring&Installation Instruction (3P3W)
Wiring Diagram
3-phase 4-wire CT operated
3-phase 3-wire CT operated
Application in IoT Solution
One-step
Direct Solution
LoRa-based
Indirect Solution
Common FAQ
Q:What's the biggest advantage of ADW300?
A:ADW300 has its built-in wireless communication module which allow it to realize 4G LTE, WiFi, NB-IoT, LoRa upstream communication without using extra IoT gateways. For the application scenarios when the meters can't be of centralized installation, ADW300 will usually be the best option for monitor 3-phase circuits that were far from each other.
Q:How should I deal with RS485 network communication malfunction?
A:First, check if the wiring of RS485 communication line was loosen or wired incorrectly.(like reversely wiring the A,B terminal).
Next,inspect if the meter’s setting of address, baud rate, check bit was correct by using keypads on the meter.
Q:What if LoRa communication of meters malfunctioned?
A:First, use USB to RS485 serial converter to connect the meter with computer. Then use adjustment software to check if setting of meter is on consensus with the setting of master station.(setting of channel and spreading factor--SF)
If setting remain the same, then it might be due to large interference of work site or the excessively far range between meter and host. In that case, it’s recommended to use chuck antenna or set a new master station nearby.
Q:What’s the difference between ADW300 and ADW300W
A:ADW300 has internal current transformers and can select compatible current transformer according to the site current to realized a secondary connection via CTs.
ADW300W on the other hand, has external current transformers.(non-detachable or it will damage the meter) This kind of design extremely ease the wiring and installation if the work-site already has CTs.
Q:What do 3×57.7/100V,3×220/380V,3×380/660V,3×100V,3×380V,3×660V represent respectively?
A:The meter’s spec of 3*100V,3*57.7/100V is suitable for high voltage power system while pairing with PT(potential transformer or voltage transformer). Beside, 3*100V represent 3-phase 3-wire and 3*57.7/100V represent 3-phase 4-wire.
The meter’s spec of 3*220/380V,3*380/660V,3*380V,3*660V is suitable for low voltage power system(directly connect with meter). Meanwhile,3*380V,3*660V represent 3-phase 3-wire and 3*220/380V,3*380/660V represent 3-phase 4-wire.
Other Question? Please contact us and we will get back to you as soon as possible.