Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring

Minimum Order Quantity : 1pc Packaging Details : carton
Delivery Time : 5-8 work days Payment Terms : T/T
Supply Ability : 5000pc/day
Place of Origin: China Brand Name: Acrel
Certification: CE Model Number: AMC16-DETT

Detail Information

Product Name: DC Multi-circuit Din Rail Energy Meter Application: Base Station
Input Voltage: DC48V
Highlight:

5G tower Multi Circuit Energy Meter

,

DC Multi-circuit Din Rail Energy Meter

,

Acrel AMC16-CETT Multi Circuit Energy Meter

Product Description

AMC16-DETT Base Station DC Multi-cirucit Energy Meter
General:
 
The AMC16-DETT base station DC power metering module is mainly designed for base stations that have sharing requirements and the switching power supply does not have separate user power metering functions. The instrument can measure DC power in six circuits, and can provide working current for the matching Hall sensor. At the same time, it can achieve zero-drift calibration through the host computer software, and has the functions of remote measurement, remote signaling, remote adjustment, real-time power measurement, and power supply quality. Abnormal alarm, information storage and processing, information interaction and other functions. This module can measure the DC power consumption of three operators respectively, provide detailed data basis for base station energy saving improvement, and provide sub-metering solutions for DC power distribution equipment.

 

Functions


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 0

 

Dimension


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 1

 

Front Panel and Wiring


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 2

 

Terminals


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 3

 

Pararmeters


Technical parameterIndex
InputDC rated voltage1 channel: -48VDC
DC current6 channels hall sensors output is 5V, current ratio can be set according to the actual ratio
Mains power monitoring1 channel transmitter input: 0-5VDC or 4-20mA
Overload capacity

Voltage:1.2times continued, 2 times continued 1s;

Current: 1.2 times continued,10 times continued 1s.

Accuracy (superposition hall sensors)1%In≤I≤10%In accuracy ±2.5%; I>10%In accuracy ±2%
Measurement resolution

Voltage output accuracy 0.01V; current output accuracy 0.01A;

power output accuracy 0.01kw; energy output accuracy 0.01kWh.

 

 

 

 

 

 

 

 

 

Functions

Basic functionMonitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED indicator display;485 communication.
Metering function

Start current: under rated voltage, when the load current value of the meter doesn’t exceed 1% of the max. current, the meter starts.

Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.

Alarm functionDC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm,memory failure alarm, AC input power failure alarm.
Timing functionSupport broadcast timing, could remote timing to the meter through RS485 communication.
Communication

1 channel RS485, baudrate 9600bps, can be set to 1200BPS, 2400bps, 4800bps.

Communication protocol: standard or custmized.

 Hall sensor power supplyPower supply output: +12V/100mA, -12V/50mA
Clock accuracy≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
Auxiliary power supplyRango de voltaje-40V ~ 60V DC
Power consumptionWhole device≤2W( no hall power supply output)
Storage

It has the storage function of historical power data and historical

alarm information, and the memory is 2MB;

Insulation resistance≥40MΩ
EnvironmentTemperatureWorking : -20℃~+60℃; storage:-40℃~+70℃
Humidity≤98% no condensation, no corrosive gas place
Altitude≤4000m
Protection levelIP20
Material flame retardent

Terminal glow wire temperature 960℃±10℃ ,shell glow wire

temperature 650℃±15℃

InstallationStandard 35mm din rail

 

 

Network


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 4

 

 

Company


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 5

 

Contact us


Acrel AMC16-CETT DC Multi-circuit Din Rail Energy Meter For Base Station And 5G Tower Six Circuits Measuring 6

You Might Be Into These
Get in touch with us

Enter Your Message

Celia.Tsui@email.acrel.cn
+8618761502682
18761502682
18761502682
18761502682